Is your window air conditioner spitting out less-than-cold air? Don't feel its breeze is as common cold as it once was? So it's time for you to roll up your sleeves and learn how to recharge a window air conditioner. Here's why we are saying that.
Air conditioners that suddenly finish emitting cool air do so because they have developed a leak in their closed-loop system. This leak has immune the refrigerant – the i substance that cools down warm air – to escape. Unless you lot refill it, your air conditioner won't return to its best performance.
How to Recharge a Window Air Conditioner
Earlier we tell you the basics of recharging your window air conditioner, brand certain that your country/county allows you to tinker with the inner parts of an air conditioner. Near states don't.
That'due south why nosotros highly recommend that you swoop into your local statute books and come up up with a dominion that allows you to attempt a projection like this. Only once you're certain that you won't be breaking any law past refilling your air conditioner should yous proceed.
one. Get the necessary supplies
You'd demand the following items to refill your window AC unit:
- Gloves
- Protective eyeglasses
- Screwdriver
- Leak detector
- Refrigerant
- Freon kit
2. Unplug the unit
Dissimilar their primal air conditioner counterparts, window AC units merely require you to unplug them from the wall socket they are plugged into to go dead. Simply unplugging them is all that is required to take them apart and inspect their inner workings.
3. Wear personal protective equipment
Make certain you take worn the gloves equally well as the protective eyeglasses before you go on. Freon, the refrigerant that y'all'll exist refilling, is toxic. It is also cryogenic and tin cause frostbite if you let it to come into contact with raw skin. So please take all the necessary precautions that y'all can.
4. Open up the Window AC unit of measurement
The majority of old window air conditioners only crave you lot to slide their front ends out of place earlier they lay bare whatever is inside them. Others, peculiarly the newer ones, will demand you to put them apart with the aid of a screwdriver. You can determine what the proper method is for your unit of measurement by going through its owner's transmission.
5. Cheque for leaks
Hither are a few methods using which y'all tin check for leaks
- Using soap: Set a mixture of lather and h2o. Lubricate all of the refrigerant transmission gear (valves, hoses, pipe etc.,) with information technology so turn on the system. If you monitor bubble formation, you have found out the leak.
- Utilize leak detector: Switch on the unit and embrace its outdoor from direct draft. Turn on the leak detector and laissez passer its probe near the ac'southward outdoor unit. If there's a leak, the leak detector, depending on its type, will requite audio or visual (or both) signals.
- Using nitrogen: This method should only exist performed past experts. It requires closing any valves that connect to upstream or downstream apparatuses, pressurizing the unit of measurement with nitrogen, monitoring its pressure at the offset and so measuring the pressure after a few minutes. If there's a notable subtract in pressure level, that means at that place's a leak.
- Using fluorescent dye: This method tin be performed by newbies. Information technology requires filling the system with a small amount of fluorescent dye so turning it on. The dye then circulates with the refrigerant and accumulates at all leak sites. You can employ a leak detection flashlight or an ultraviolet lamp to pinpoint the position of leak (it will exist glowing).
6. Fix the leak
Provided your unit has a very boring leak, y'all don't need to fix information technology as only 'boosting' the system volition be plenty to recoup for refrigerant leakage. Yet, if the leak is fast, you may accept to solder the area, from which the refrigerant is leaking, together once again.
7. Connect the valves to the compressor
Go through your unit's manual to locate its compressor and the 2 lines that are coming out of it. One time you have done that, attach the compressor line to the service valve from your kit. There should still be one, free line coming off the compressor. Attach it to the tap valve. Both these valves will be included in your Freon kit.
8. Connect the valves to the Freon kit
Virtually all Freon kits come with a detailed diagram showing you how to connect the 2 valves (service and tap) to the Freon'due south container. You should be able to use this diagram to correctly position the refrigerant tank/Freon tank betwixt the two valves.
Final Step: Recharge your window air conditioner
Brand sure that everything is connected snugly and that there's no chance for any leakage. And then, turn on your window AC unit and ramp it up to its highest power setting. With the service and tap valves at present connecting the Freon tank to the air conditioner, what will happen is that the refrigerant will start flowing from the tank and into the unit.
Consult your unit'southward manual to make up one's mind the amount of Freon your unit requires. Once the gauge on the Freon tank indicates that the limit has been reached, power down the unit. Unplug the air conditioner, remove the service and tap valves and turn on your air conditioner.
Conclusion
To summarize what nosotros accept said by at present, information technology is illegal in almost parts of the country for an unlicensed person to recharge their window air conditioner. However, even if you lot're allowed by law to legally power upward your unit, consult a professional if at any point you have striking a snag.
Aside from that, it's equally crucial that you but recharge that corporeality of refrigerant that is required. EPA warns that while overcharged systems have greater potential for leakage, undercharged ones take higher running costs and are less efficient.